PA-1960
High-power mono PA amplifier
- 1 x 960 W
- Additional, adjustable priority input with switchable priority function
- 100 V slave input for inserting the amplifier into a 100 V speaker line
- Switchable 400 Hz high-pass filter 6 dB/oct.
- 2 insertion facilities on the rear panel for optional modules with…
+ more
High-power mono PA amplifier
- 1 x 960 W
- Additional, adjustable priority input with switchable priority function
- 100 V slave input for inserting the amplifier into a 100 V speaker line
- Switchable 400 Hz high-pass filter 6 dB/oct.
- 2 insertion facilities on the rear panel for optional modules with…
Productinfos
Supplies
Technical specifications
Services
PA-1960
High-power mono PA amplifier
- 1 x 960 W
- Additional, adjustable priority input with switchable priority function
- 100 V slave input for inserting the amplifier into a 100 V speaker line
- Switchable 400 Hz high-pass filter 6 dB/oct.
- 2 insertion facilities on the rear panel for optional modules with the following features:
- PA-6FD: fault detection module
- PA-6FM: fault monitoring module
- Connection for external on/off switch (remote start)
- Temperature-controlled fan, continuously adjustable
- LED indication for fault, protect, clip, signal, priority
- Mains operation or 24 V emergency power operation
Manufacturer information:
MONACOR INTERNATIONAL GmbH & Co. KG
Zum Falsch 36
28307 Bremen
Germany
info@monacor.com
Zum Falsch 36
28307 Bremen
Germany
info@monacor.com
Safety Notes and Warning Messages
The unit uses dangerous mains voltage. Leave servicing to skilled personnel only and do not insert anything into the air vents. Inexpert handling may result in electric shock.
During operation, there may be a hazard of contact with a dangerous voltage of up to 100 V at the speaker terminals. Always switch off the amplifier before making or changing any connections.
Do not operate the unit and disconnect the mains plug from the socket immediately if the unit or the mains cable is visibly damaged; if a defect might have occurred after the unit was dropped or suffered a similar accident, if malfunctions occur. In any case, the unit must be repaired by skilled personnel.
The unit is suitable for indoor use only. Protect it against dripping water and splash water, high air humidity and heat (admissible ambient temperature range: 0 - 40 °C).
Never pull the mains cable to disconnect the mains plug from the socket, always seize the plug.
The heat generated inside the unit must be dissipated by air circulation; never cover the air vents of the housing.
If the unit is to be put out of operation permanently, take it to a local recycling plant for a disposal which is not harmful to the environment.
During operation, there may be a hazard of contact with a dangerous voltage of up to 100 V at the speaker terminals. Always switch off the amplifier before making or changing any connections.
Do not operate the unit and disconnect the mains plug from the socket immediately if the unit or the mains cable is visibly damaged; if a defect might have occurred after the unit was dropped or suffered a similar accident, if malfunctions occur. In any case, the unit must be repaired by skilled personnel.
The unit is suitable for indoor use only. Protect it against dripping water and splash water, high air humidity and heat (admissible ambient temperature range: 0 - 40 °C).
Never pull the mains cable to disconnect the mains plug from the socket, always seize the plug.
The heat generated inside the unit must be dissipated by air circulation; never cover the air vents of the housing.
If the unit is to be put out of operation permanently, take it to a local recycling plant for a disposal which is not harmful to the environment.
Technical specifications PA-1960
PA-1960 | |
---|---|
Peak output power | 960 W |
Power rating | 960 W |
Power rating at 100 V | 960 W |
Power rating at 70 V | 960 W |
Output impedance | 75 V/5.6 Ω, 85 V/7.2 Ω, 100 V/10 Ω |
Channels | 1 |
Inputs | 0.775 V/60 kΩ, bal. |
Frequency range | 35-20,000 Hz |
S/N ratio | > 100 dB |
THD | < 0.4% |
Power supply |
˜ 230 V/50 Hz/2,600 VA, DC 24 V/80 A |
Mains voltage | ~ 230 V |
Mains frequency | 50 Hz |
Power consumption, operation | 2,600 VA |
Standby current | DC 24 V |
Operating voltage (possible alternative) | 80 A |
Admiss. ambient temp. | 0-40 °C |
Width | 483 mm |
Height | 133 mm |
Depth | 374 mm |
Rack units, RU | 3 |
Weight | 25 kg |
Connections |
screw contacts (inputs) screw contacts (speakers) |
Packaging dimensions (W x H x L) | 0.54 x 0.21 x 0.48 m |
Gross weight | 28.26 kg |
Net weight | 26.3 kg |
PA-1960 | |
---|---|
EAN code | 4007754203967 |
Net weight | 26.3 kg |
MONACOR offers more ...
When it comes to quality, MONACOR INTERNATIONAL leaves nothing to chance and relies on its own strengths. Our proactive quality policy ensures the greatest possible security. Accredited test labs support and document tight tolerance limits, and conduct extensive quality assurance checks of our products. This means that you benefit from very high standards of quality – for all products.
-